MODAPS PCR 15-007
PCR Number | 15-007 |
---|---|
Date | 2015-04-02 |
Initiator | Gang Ye |
Abstract | PGE96 v6.0.2 Install PGE96 6.0.2 to nrt1/nrt2 to correct C5 PGE96 failure. |
Problem Statement | C5 PGE96 failed on nrt1/2 while C6 PGE96 works fine.The best solution would simply be to start running C6 instead of C5. C5 PGE01 should be able to use products from C6 versions of PGE96. Completed test run - C5 NRT PGE01 has no trouble when running off of C6 PGE96 products. |
Description of Change | Install PGE96 6.0.2 into nrt1/2. |
Products Affected | None |
Software Affected | PGE96 v6.0.2 |
Processing String to Receive the Change | Aqua NRT |
Downstream Product Effects | NRT Aqua PGE01 will continue on nrt1/2 |
Data Granules to be Used for Science Testing | Not required. |
Justification | PGE96 will run on nrt1/2. |
Effective Date for Implementation of Change | 2015-03-03 |
Status | Gang Ye approved on 03/03/2015. |