MODAPS PCR 22-011
PCR Number | 22-011 |
---|---|
Date | 2022-08-30 |
Initiator | Carol Davidson & Praveen Noojipady on behalf of Alexei Lyapustin |
Abstract | PGE113 6.1.21 Code revision to populate InputPointer accurately when single instrument dataset is used as input. |
Problem Statement | The PGE113 output INPUTPOINTER metadata field was incomplete when only one sensor had inputs (either Aqua or Terra was not available). |
Description of Change | Updated meta.cpp by adding intermediate input pointer arrays to just store these non-empty input filenames from the original input pointer arrays and used the intermediate input pointer arrays to write out INPUTPOINTER. |
Products Affected | Daily C61 L3 Tiled MAIAC products, MCD19A1, MCD19A2, and MCD19A3 |
Software Affected | PGE113 6.1.21 |
Processing String to Receive the Change | Terra and Aqua Forward Processing. Terra and Aqua Reprocessing. NRT |
Downstream Product Effects | None. |
Data Granules to be Used for Science Testing | The PGE113 INPUTPOINTER correction was successfully tested through MODAPS ops instance test in AS1914. |
Justification | The revision was needed in order to have accurate and complete metadata in the MAIAC outputs during all processing cases. |
Effective Date for Implementation of Change | The changes to the PGE113 was put in to resume the MAIAC reprocessing, starting PGE_StartTime of 2003-01-01 on calendar day 8/22/22. |
Status | Major algorithm development completed. Sadashiva Devadiga approved 09/08/2022. Sudipta Sarkar approved 09/08/2022. |