MODAPS PCR 15-020

PCR Number 15-020
Date 2015-05-27
Initiator Dr. Zhengming Wan
Abstract PGE11 v6.4.11. Raising upper boundary from 17200 to 17700 so that daytime LST value not exceeding 354K (81C)
Problem Statement LST saturates at 344K and hence can't retrieve true value of LST > 344 K.
Description of Change Raise the upper limit for LST while screening for good retrievals.
Products Affected MxD11A1, MxD11B1
Software Affected PGE11 v6.4.11
Processing String to Receive the Change Terra Reprocessing and Aqua Reprocessing
Downstream Product Effects None.
Data Granules to be Used for Science Testing Process Terra and Aqua days 2012169 - 2012232 generating global daily LST products using the C6 L1B as input.2010-059
Justification LST over certain desert area can exceed the preset maximum of 344K. The time series analysis of the day time LST over these area reveal LST as saturated at 344K, thereby failing to retrieve any true LST value exceeding this maximum. This change to C6 will let the algorithm retrieve the observed maximum LST. Science team and LDOPE request that this change be put in operation at the leading edge of the C6 reprocessing. Re-reprocessing of LST will need significant resource and percentage of retrieval affected by this error in the C6 data reprocessed until now isn't significant enough to warrant an immediate re-reprocessing of the LST from the beginning of the mission.
Effective Date for Implementation of Change Completed.
Status Major algorithm development completed. Sadashiva Devadiga approved on 05/27/2015. Michael King approved on 06/04/2015.