MODAPS PCR 14-026

PCR Number 14-026
Date 2014-10-17
Initiator Jim Ray
Abstract To implement updated code that addresses a minor bug fix in the aeronet subset process.
Problem Statement Segmentation failure in operational processing from failure to catch bad geolocation.
Description of Change Use the return value from the downstream routine indicating success or bad geolocation.
Products Affected MODARNSS, MODFNSS, MYDARNSS, MYDFNSS
Software Affected PGE90 v6.0.12
Processing String to Receive the Change Terra Forward, Aqua Forward
Downstream Product Effects None
Data Granules to be Used for Science Testing Ran science test at the SCF and verified by the science team. Unit test of the specific cases ran and verified by STIG. Global science test waived.2010-059
Justification Failure during operational processing from geolocation errors result in missing AERONET subset. Algorithm fix will produce the subsets by ignoring scan lines with geolocation anomaly.
Effective Date for Implementation of Change Completed.
Status Science test completed; results evaluated by the Science Team at SCF and MODAPS. Sadashiva Devadiga approved on 10/20/2014. Michael King approved on 10/21/2014.