MODAPS PCR 13-014
PCR Number | 13-014 |
---|---|
Date | 2013-07-24 |
Initiator | Sadashiva Devadiga |
Abstract | PGE107 Loader Module modified to improve the outputs when C5 files are used as inputs. |
Problem Statement | PGE107 was using M*D09CSR coarse resolution in C5 for certain PGE11 versions run (beyond 5.3.30) that were problematic. |
Description of Change | The Loader Module was modified to check if all the M*D09CRS files are coming from C5 then the M*D09 files are used and the coarse M*D09CRS is made inside PGE107. On the other hand if all M*D09CRS are coming from C6 then those (M*D09CRS) are used as inputs. If the M*D09CRS/M*D09 are a mixture of C5 and C6 then the PGE will result in RunErr. |
Products Affected | MOBGLSR_C05K, MOBGLSR_C20K, MOBGLSR_E05K, MOBGLSR_E20K, MOBGLSRFC_C05K, MOBGLSRFC_C20K, MOBGLSRFC_E05K, MOBGLSRFC_E20K, MOBGLSRFC_W05KMOBGLSRFC_W20K, MOBGLSR_W05K, MOBGLSR_W20K |
Software Affected | PGE107.v6.0.7Recipe: [AP]M1M_C6_L28m 6.0.7 Production Rule: PGE107_LoaderModule.pl |
Processing String to Receive the Change | Terra Forward, Terra Reprocessing, Aqua Forward, Aqua Reprocessing |
Downstream Product Effects | None. |
Data Granules to be Used for Science Testing | Run 2 day period test. 1 day should have C6 M*D09CRS as inputs and the other C5 M*D09CRS and M*D09 as inputs. In the test that C6 M*D09CRS inputs are used these should be used as the inputs for the PGE. In the test that both C5 M*D09CRS and M*D09 are used as inputs the M*D09 should be used as the inputs for the PGE. |
Justification | This change will improve the outputs when C5 files are used as inputs. |
Effective Date for Implementation of Change | Completed. |
Status | Science test completed; results evaluated by the LDOPE and science team. Sadashiva Devadiga and Bill Ridgway approved on 07/24/2013. |