MODAPS PCR 08-004

PCR Number 08-004
Date 2008-06-20
Initiator Jim Ray
Abstract Fix to correct failure due to invalid input metadata.
Problem Statement PGE75's MOD_PR09C.exe process had failed because its inputs had metadata values that had not been anticipated.
Description of Change To the IDS metadata-reading algorithm was added a sanity check forBOUNDINGCOORDINATE metadata, to ensure that such metadata values are between -90.0 and +90.0 (for latitude-derived coordinates) or between -180.0 and +180.0 (for longitude-derived coordinates).
Products Affected M[O|Y]D09CMG and M[O|Y]D09CMA
Software Affected PGE75
Processing String to Receive the Change Terra Forward, Terra Reprocessing, Aqua Forward, Aqua Reprocessing
Downstream Product Effects None.
Data Granules to be Used for Science Testing Run one day global test for day 2006-301.
Justification To prevent the occasional failure of PGE75's primary process.
Effective Date for Implementation of Change  
Status Science test completed; results evaluated by LDOPE. Sadashiva Devadigaapproved for Land, Vincent Salomonsom approved on 06/24/08.