MODAPS PCR 14-013
PCR Number | 14-013 |
---|---|
Date | 2014-07-15 |
Initiator | Bill Ridgway |
Abstract | To implement updates in PGE04 v6.0.38, PGE04 v6.0.39 with a required algorithm fix to restore product quality. |
Problem Statement | MYD05_L2 Water_Vapor_Near_Infrared SDS was found to have unacceptable noise in scenes with broken clouds. This issue was traced to the use of re-aggregated Band1/Band2 radiances (MYD021KM_RA) as inputs. The algorithm uses Band2 & Band17, which are adversely de-registered by the RA process. |
Description of Change | Altered use of RA flag in MOD_PR04_05 so that MYD021KM_RA files are ignored by PGE05. |
Products Affected | MYD05_L2 product has restored quality of Water_Vapor_Near_Infrared retrievals. |
Software Affected | PGE04 v6.0.38, PGE04 v6.0.39 |
Processing String to Receive the Change | Aqua Forward, Aqua Reprocessing |
Downstream Product Effects | MYD05_L2 is used in production of MYDATML2 and Atmosphere L3 products plus browse products. |
Data Granules to be Used for Science Testing | Aqua MYD05_L2 products generated for 2008/275 and 2011/20742010-059COMPLETED LAADS AS 1194/1195 |
Justification | Required algorithm fix to restore product quality from degraded status. |
Effective Date for Implementation of Change | ASAP for Aqua reprocessing and forward processing. |
Status | Algorithm development and testing completed. Steve Platnick approved on 7/15/2014. Michael King approved on 7/23/2014. |